How do I measure pump output?

Bucket, clock, and patience

BAKERSFIELD, California — Measuring pump output means finding out how many gallons per minute your pump really delivers, which is rarely the number stamped on the nameplate. You can do it with a flow meter, with a bucket and a stopwatch on small systems, or by timing how long it takes to fill a tank of known size. All it takes is some arithmetic and a willingness to be disappointed by a pump that has worked hard for twenty years. For more farm humor, see this tale of city folk who mistake Wi-Fi for irrigation, which is mostly about a pump that was never actually plugged in.

Use a flow meter if you have one

An inline meter with a totalizer is the easiest route. Note the reading, run the pump for a set time, note the reading again and divide the volume by the minutes. Do it when the system is running at its normal working pressure, because pump output changes with pressure. A flow reading at the wrong pressure is accurate and useless, which is a very farm thing to be.

The bucket and stopwatch method

For small systems, time how long it takes to fill a container of known volume, such as a five-gallon bucket, from one outlet. Divide the volume by the seconds, then multiply by sixty to get gallons per minute. This works for a single hose or sprinkler head, but for a whole system you have to measure many outlets and add them up, which gets old fast. It does work well for checking a drip emitter or a single nozzle.

The tank-fill method

If you have a tank or trough of known capacity, such as a stock tank, empty it, then time the pump while it fills. Divide gallons by minutes. Make sure the tank's volume is accurate. Measuring its length, width and depth lets you calculate cubic feet, and one cubic foot holds about 7.5 gallons. Keep in mind the water level in the source may drop as you pump, which can slow flow and give a lower result.

Make the number useful

Once you know gallons per minute, convert it to acre-inches per hour. A flow of about 450 gallons per minute delivers roughly one acre-inch per hour over an acre, since an acre-inch is around 27,000 gallons. Divide your flow by 450 to get acre-inches per hour. Then compare with the sprinkler or pivot chart. If the numbers don't match, something is leaking, clogged, worn or set wrong.

Check pressure and power too

Output relates to pressure and the pump curve published by the manufacturer. Measure pressure at the pump and at the far end. Note the electric or fuel use. If flow drops from last year at the same pressure, suspect wear, a clogged intake, or a falling water table. Ask a pump dealer or irrigation specialist for a test; extension and NRCS staff know who does them. Nebraska CropWatch offers irrigation management material.

Test once a year, write it down, and compare. Pumps rarely quit without warning; they just get a little slower each season while we assume not to notice.