How do I size a well pump?

Flow, head and the pump curve

SIOUX CITY, Iowa — Sizing a well pump comes down to two numbers: how many gallons per minute you need, and how much pressure the pump has to produce, expressed as total dynamic head. Match those two to a manufacturer's pump curve and you'll land on the right pump without guessing.

Too big a pump drains the well and short-cycles. Too small a pump leaves the hydrant dribbling. The middle ground takes about an hour with a pencil.

Step One: Work Out Your Flow Demand

List everything that might run at once. For livestock, estimate daily drinking needs and the peak rate at which tanks must refill. For irrigation, use the flow your sprinklers or drip zones require. For a house or shop, add fixtures.

Your extension office or livestock specialist publishes water-use guidance by species, and beef.unl.edu from Nebraska is one place to read about cattle water needs. Don't forget the well's own limit: the pump can't take more than the well gives. Get the sustained yield from the well log or a pump test.

Step Two: Calculate Total Dynamic Head

Total dynamic head is the sum of:

  1. Vertical lift: the distance from the pumping water level up to where the water leaves, such as a tank top or the pressure tank.
  2. Pressure requirement: the working pressure you need at the outlet, converted to feet of head. Each pound per square inch equals a bit over two feet of head.
  3. Friction loss: the pressure lost to pipe length, diameter and fittings.

Friction loss tables are published by pipe makers. Longer, thinner pipe means higher loss. If you're running a long line to a distant tank, friction can be the largest piece.

Step Three: Read the Pump Curve

Every manufacturer publishes a performance curve showing flow against head for each pump model. Find your head on one axis and your flow on the other and see where they cross. You want a pump that delivers your numbers close to the middle of its curve, where efficiency is best.

If your point sits far off to one side, try the next model up or down. Check the motor's horsepower and electrical requirements as well, including whether you have single-phase or three-phase power, and the voltage. A mismatch there ends many a Saturday project.

Step Four: Account for Well Diameter and Depth

Submersible pumps have to physically fit. Check the casing inside diameter against the pump's diameter, and set the pump below the lowest pumping level with room to spare but above the bottom, where sediment settles. Your drill log should list the casing size and depth.

For a pressure system, the pressure tank size and the pump's flow rate together determine how often the pump cycles. A tank that's too small makes the pump start and stop constantly, which wears the motor. Tank makers list the draw-down capacity, so compare it to the pump's flow.

Step Five: Add a Margin, Then Check With Someone

Add a modest safety margin to your flow and head figures, but don't pad them to the moon. Oversized pumps cost more to run and may exceed the well's yield. Then ask a licensed well contractor or pump supplier to check your math, since they know the quirks of local aquifers and sandy wells.

If the well is a weak producer, plan for storage: a pump that fills a tank slowly may serve you better than one that tries to deliver peak flow on demand. For irrigation questions, CropWatch has useful irrigation planning material, and the Iowa State Ag Decision Maker pages cover costs of equipment and operations.

The Short Version

Write down flow, head and well limits. Find the pump whose curve passes through your point near the middle. Confirm it fits the casing and your electrical supply, and have a pro look over the numbers. After that you're allowed one smug moment at the tank when it fills right on time.