How do I use yield monitors in trials?

Calibrate first, trust second

FARGO, North Dakota — You use a yield monitor in trials by calibrating it carefully, harvesting each plot or strip as a separate load with clear start and stop points, and checking the monitor's numbers against weighed grain. Yield monitors can be handy for large strip trials where hand weighing isn't practical. They're also easy to misuse, so treat the monitor as a good estimate that needs checking, not as a certified scale.

Know what a monitor can and can't do

A yield monitor measures flow, moisture, and position as the combine moves. Its accuracy depends on calibration, ground speed changes, header position, grain flow, and how plots are bounded. In a plot with short passes and starts and stops, delays and lag can smear data from one plot into the next. For small replicated plots, a plot combine with a scale is more reliable.

Monitors do work well for wide strips and field-scale comparisons, where each strip is long enough to smooth out lag and edge effects.

Lag matters. A monitor reports yield for grain that entered the machine several seconds earlier, so the reading at the end of a strip reflects the end of the strip only after the grain has cleared the machine. Good software lets you set a delay value, and a trial with short strips needs extra attention to it. Ask your dealer how your system handles flow delay, and test it on a known boundary.

Calibrate properly

Follow the manufacturer's calibration procedure, and calibrate for each crop and for different flow rates. Weigh calibration loads on a certified scale, such as a grain cart scale or a scale at the elevator. Calibrate again if conditions change a lot, such as a different crop moisture or a big shift in yield.

Record the calibration date, loads, and settings. Check the moisture sensor against a handheld meter or elevator numbers.

A single calibration across a wide range of flow rates tends to be less accurate than separate points. Try to run loads at slow, medium, and fast flow, then compare monitor weight with scale weight on each. If your yield varies strongly by variety, calibrate with representative loads from the high- and low-yielding strips, since the relationship between flow and weight can drift.

Design for the monitor

Make strips wide enough for the header and long enough for the monitor to settle, and plan for borders where the combine speed or header height changes. Replicate and randomize strips if possible, so a pattern in the field doesn't masquerade as a variety effect. Keep the combine speed and header height steady through the trial.

Mark the start and end of each strip with flags or other markers and make sure the operator knows the plan. Use the monitor's load or field-boundary function to tag each plot.

Keep the combine moving at a constant speed through the strip, and avoid stopping to unload in the middle of a strip. If you have to, mark the spot and exclude it. Harvest the strips in a consistent direction, because uphill and downhill passes can give different readings. Write down the order of passes in the field book.

Clean and process the data

Yield monitor files often contain errors: spikes at the start and end of passes, overlap areas, and points when the header was raised. Use cleaning tools in your software or a spreadsheet to remove those points. Trim the first and last section of each strip, and document your rules.

Compare plot averages with the weighed load from each strip when possible. If the monitor numbers differ systematically, apply a correction and note it in your report.

Keep the raw file untouched and work from a copy, so you can always go back. Write down every cleaning step, such as removing points below a set speed or trimming the first and last stretch of each pass. If you'd explain the steps to a neighbor in a sentence or two, you're probably doing it sensibly, and if you can't explain them, simplify. Compare plot averages with the weighed load from each strip when possible. If the monitor numbers differ systematically, apply a correction and note it in your report.

Analyze with care

Use the cleaned averages per strip or per plot, and analyze them with a method that fits your design. If strips aren't replicated, treat the comparison cautiously, since field variation may explain a difference. Overlay with soil maps and, if you have them, earlier yield maps to check whether the layout favored one variety.

Remember that monitor data has its own error on top of field variation. Differences of a small size often fall inside that error.

Your equipment dealer can help with calibration. For method guides, see Nebraska CropWatch, Iowa State's Ag Decision Maker, and Purdue Extension. Farmdoc Daily discusses interpreting field-scale data, and SARE has on-farm research guidance.

A yield monitor is a good tool for the right job. Calibrate it, bound your strips, check against a scale, and it'll give you numbers worth acting on.

Look at the spatial pattern, not just the averages. Plot the cleaned yield points on a map and see whether the differences line up with the strip boundaries or with soil types. If they follow the soil map and not the strips, the variety isn't the cause. This overlay is where a yield monitor trial earns its keep, because the data shows the field as well as the varieties.