What is the best way to catch can test?

Cans, spacing and a calm day

BEATRICE, Nebraska — The best way to run a catch can test is to use identical straight-sided containers, space them evenly along a line or grid under your sprinklers, run the system at normal operating conditions on a calm day, then measure the water in each can and calculate how even the application was. Do the setup carefully and the arithmetic is easy. Do it carelessly and you'll chase problems that don't exist.

Here's a practical walk through the process, tuned for pivots and fixed sprinkler layouts. Local Extension guidance may specify spacing or methods for your system, so check it before you start.

Gather the right containers and tools

Use identical containers with straight sides and a wide mouth, such as the same size of cans or straight-sided plastic cups. Identical matters, because different shapes catch differently. Make sure they're deep enough that water won't splash out. Weighted bases or a little soil in the bottom keep them from blowing over.

You'll also need a measuring cylinder or graduated container, a ruler if you read depth, flags to mark positions, a tape, a notebook and a pressure gauge. A watch helps you record run time. Level ground and a few extra hands speed everything up. Number the cans and keep that numbering in your notebook so you know which result came from where.

Set the layout

For a center pivot, place cans in a straight line from near the pivot point out toward the end, along a span where the crop isn't tall enough to interfere. Use consistent spacing. Closer spacing gives more detail, and your Extension guide will suggest a spacing for your machine. Because outer areas cover more ground, some methods weight the results by position.

For a solid-set or hand-move sprinkler layout, put cans in a grid between several sprinklers, covering the full overlap pattern. Keep them away from the base of a sprinkler where droplets hit hard. Set cans at a consistent height, and be sure nothing like tall crop or wires blocks the spray.

Run the test under normal conditions

Pick a day with little wind. Strong wind distorts the pattern and your results won't reflect the system. Run at normal operating pressure and normal speed, and record the pressure at several points if you have a gauge. Don't adjust anything just for the test.

Let the system run until cans collect enough water to measure with confidence. With pivots, you set the machine so it passes over the can line, and you measure after it clears. Don't let cans overflow, and note any can that tipped or got hit by an animal. Throw out that data point or re-run it.

Measure and record

Read each can promptly, before evaporation changes the volume. Pour into the measuring cylinder, or measure depth with a ruler if the cans are the same diameter. Write each result next to its position number. Some people photograph the cans lined up, a quick visual that shows the pattern.

Convert volumes to depth if needed, using the opening area of the container. Keep units consistent. Check your data for outliers. If one can reads wildly different from neighbors, look at whether it was tilted or partly shielded.

Calculate and use the results

Average all readings. Then average the lowest quarter of readings and divide that by the overall average to get low-quarter distribution uniformity. Your Extension guide may also use coefficient of uniformity. Compare your numbers to the targets listed for your system type, and don't be surprised if the first test is humbling.

A few finishing tips. Take photos of the layout, record the time the machine passed each can and note any wind gusts, since those details explain odd results later. Use the same cans next year so comparisons stay fair. If your Extension office offers a loaner kit or a field day, take advantage, because watching someone run the test once makes your own first attempt far smoother. The NRCS and the Extension network can also point you toward local irrigation specialists. Repeat the test after any repair so you can see what the fix actually bought you, and keep the old sheets for comparison. Bring a helper, a thermos and a sense of humor, since walking a quarter mile of cans in a crop is a workout.

Map the pattern. Gaps, stripes or low zones near the end of a lateral help you trace causes: worn nozzles, wrong nozzle size, low pressure, leaks, misaligned sprinklers or tower speed problems. Fix and re-test. CropWatch and Nebraska Extension publish methods and worksheets, and NRCS can help evaluate your system and discuss conservation assistance. You will never look at a pivot the same way again, which is probably healthy.