How do I calibrate a feed mixer?

Check your scale before trusting the ration

OSKALOOSA, Iowa — To calibrate a feed mixer, you check its scale against known weights, adjust the indicator, and then test it again with real feed. A mixer scale that reads wrong by even a few percent changes every ingredient in the ration and slowly drifts your herd away from what the nutritionist formulated. It's a short job with the right equipment, and it should be done at least once a year and any time you replace load cells, hit something with the wagon, or suspect the readings.

Understand what's being calibrated

Most mixers weigh with load cells that sit under the frame or at the hitch points, connected to an indicator in the cab. Calibration tells the indicator how to turn the electrical signal from the load cells into pounds. If a load cell is damaged, wet or out of level, or the wagon is parked on a slope, the readout can be wrong even when the electronics are fine. Read the manufacturer's manual first, since calibration procedures differ by brand and model.

Gather known weights

You need something you trust to weigh. Options include certified test weights, or a loaded truck you've weighed on a certified scale before and after. Many feed mills and elevators have a public scale you can use. Some dealers offer a calibration service with certified weights, which is worth the cost if you aren't sure. Avoid guessing with bags of feed of unknown weight, since the printed bag weight isn't a calibration standard.

Do the procedure on level ground

A general outline looks like this:

  1. Park the empty mixer on a hard, level surface and make sure nothing is stuck to the box.
  2. Zero the indicator with the box empty, following the manual.
  3. Add known weights in steps and compare the display each time.
  4. Adjust the span or calibration factor in the indicator if readings are off.
  5. Repeat with the weights removed to check for return to zero.

Check also that the display is stable when the tractor is running and the PTO is engaged, as vibration can cause drift. If the readout jumps or doesn't return to zero, suspect a worn load cell, water in a connector or a loose cable.

Verify with a real load

After calibration, load a known batch and compare the scale total against something independent, such as the weight at a certified scale. Many dairies check periodically by loading a ration and weighing the loaded wagon on the elevator scale. If the difference is more than your nutritionist or the equipment dealer suggests is acceptable, repeat the process or have it serviced. Ask the dealer about acceptable tolerances for your model.

Keep a calibration log

Write down the date of each check in your own records, who did it, and what you found. If you track the ration over time, you can tell whether a milk or intake shift came before or after a scale change. Check the scale after major repairs, welding on the frame or replacing load cells.

Other things that affect accuracy

Don't forget the loader bucket scale, if you use one for ingredients. Keep the mixer clean of caked feed, which adds weight. Train everyone who loads the mixer to read the indicator the same way. The University of Nebraska tractor test lab deals with tractor performance rather than scales, but your dealer or Penn State Extension can point you to the right references. A mixer scale is only as good as the last time somebody checked it, and that is usually longer ago than anyone admits.