How do I manage gas hazards in manure storage?

Know the gases, control the release

AMES, Iowa — Manure storage gives off four gases that matter: hydrogen sulfide, methane, ammonia, and carbon dioxide. You manage them by controlling when and how manure is disturbed, moving air through the space, measuring what's in it, and staying out of enclosed spaces unless a trained team runs the entry. Smell alone will not protect you.

The big danger moment is agitation. Stirring a pit that has been sitting breaks up the crust and releases a burst of gas that has been building. That surge is why many serious incidents happen during pump-out.

What each gas does

Hydrogen sulfide smells like rotten eggs at low levels but deadens your nose at higher ones, and high exposure can drop a person in a breath or two. Methane is flammable and can displace oxygen. Carbon dioxide displaces oxygen. Ammonia irritates eyes and lungs and rises from manure surfaces, especially after agitation or in warm weather. Exact exposure limits are published by OSHA and NIOSH; look them up rather than relying on a number you half remember.

Plan agitation like a job with a hazard

Before agitating:

  1. Move people and animals out of buildings above or next to the pit.
  2. Open doors, curtains, and fans to bring in as much fresh air as possible.
  3. Agitate on a day with some wind when you can, and avoid still, humid days.
  4. Start the pump at the outside end and stay away from the pit opening.
  5. Keep children and visitors clear of the area.

Animals in an attached barn are at risk too, and cattle have died during agitation. If you can, empty the barn first.

Monitor, don't guess

Use a calibrated multi-gas monitor worn at the breathing zone, and consider fixed detectors with alarms in enclosed pump rooms. The NIOSH agriculture program has guidance on manure gas hazards, and the OSHA agriculture page covers confined space rules.

Reduce what gets released

You can't stop manure from making gas, but you can cut the exposure. Keep manure moving rather than letting thick crusts and solids settle. Use agitation points that stir from outside the building when possible. Keep pump pits covered. Consider handling manure with a contractor who has the right gear and experience.

Emergency response

If someone collapses near a pit, the rule is: don't follow them in. Call emergency services first and give them the exact location and the fact that it's a manure gas incident. Ventilate from outside if you can do so without entering. Only people with supplied air and training should enter. AgriSafe and your state extension office can help find trainings for your crew and local responders.

Put these rules on a laminated card by the pump controls and in every employee's onboarding. The gases don't care how many years you've been doing this. They've fooled people with decades of experience, and the people with decades of experience are usually the ones who say so afterward, if they get the chance.