How do I use near-infrared feed testing?

Fast numbers, if the sample is right

KEARNEY, Nebraska — Near-infrared testing, called NIR or NIRS, shines light on a ground, dried feed sample and reads how the sample absorbs it. A computer model, built from earlier wet chemistry results, converts that reading into estimates of protein, fiber, moisture and other values. It's fast and cheap, which is why most forage labs rely on it for routine analysis.

It's good, but it's an estimate, so it pays to know what it does well and where it needs backup.

What NIR does well

NIR does a good job on the main forage numbers: dry matter, crude protein, fiber fractions such as NDF and ADF, starch in corn silage, and estimates of energy and fiber digestibility. It can run a lot of samples in a short time and cost less than wet chemistry, so you can test every cutting or every bunker.

Because it's quick, you can track changes in forage over a season and adjust rations before a problem hits the bunk.

Where it falls short

NIR is weaker for minerals, where it may estimate a few poorly and others well, and for unusual feeds that aren't well represented in the lab's calibration. A calibration built on alfalfa won't be as good with a byproduct blend it hasn't seen. If you're feeding something odd, ask the lab whether it has a calibration for it and whether it recommends wet chemistry.

Wet chemistry, where the sample is analyzed by standard lab methods, is slower and costs more, but it's the reference. Some labs run a share of samples through both to check their calibration.

Pick a lab that checks itself

Ask the lab how often it validates its calibrations, whether it takes part in proficiency testing with other labs, and which feed types it handles. A lab that can answer those clearly is generally a better bet. Your nutritionist and extension office can suggest labs that work well in your region. Some groups run certification programs for forage labs, so ask if your lab participates.

Handheld and on-machine units

Portable NIR instruments are available for farm use, and some can mount on a forage harvester or in a mixer wagon to read dry matter as feed moves through. They can help you adjust rations quickly, particularly for moisture. Still, readings from fresh, wet, uneven samples are less precise than lab readings on dried, ground samples. Treat them as a monitor, and check against the lab regularly.

Sample and prepare well

NIR speed doesn't excuse bad sampling. Take a representative sample, as described in our silage sampling article, keep it cold and send it fast. If you're drying your own samples for a lab, follow the lab's instructions, since drying temperature affects results.

Using the results

Compare NIR results from sample to sample, and keep a running record by field, cutting and bunker. Big swings usually mean something changed in the field or storage. Feed those numbers into ration balancing with your nutritionist, and send a duplicate sample to wet chemistry if a number looks odd.

Getting started

  1. Ask your nutritionist or extension office which labs they trust.
  2. Ask each lab about its calibrations and proficiency checks.
  3. Sample every forage lot the same way.
  4. Test regularly, not just when things go wrong.
  5. Back up surprising numbers with wet chemistry.
  6. Keep records and chart your trends.

For more, see Extension.org, Iowa State's Ag Decision Maker and Penn State Extension. The National Agricultural Library can point to the research behind NIR calibrations.

NIR won't make the feed better. It just tells you the truth sooner, which is worth a lot.