What causes high bacteria counts?
Four usual suspects
LANCASTER, Pennsylvania — High bacteria counts in raw milk usually come from one of four places: dirty equipment, poor cooling, dirty teats and cows, or mastitis. Occasionally it's a combination, and occasionally it's the well. Finding which one is a matter of checking each in order, starting with the cheapest.
The pattern in your lab report gives clues. Different counts point to different sources, so start by reading which counts are high.
Equipment not washed clean
A film of milk residue and bacteria builds up on rubber, steel and pipeline joints when the wash fails. Check wash water temperature at the start and end of the cycle, detergent and acid concentration, water hardness and contact time. Failing any one leaves biofilm. Look inside the bulk tank outlet, gaskets, inflations, claws and air inlets. A high laboratory pasteurized count often points here, since heat-tolerant bacteria survive the wash.
Slow or inadequate cooling
Bacteria double fast at warm temperature. If milk takes too long to cool, the count climbs. Check tank temperature, compressor performance, cooling equipment such as plate coolers, tank agitator and the amount of milk in the tank. A tank that is too full at the first milking may cool too slowly, and a dirty condenser coil can make a good compressor act weak. A high preliminary incubation count often points here.
Dirty teats and udders
Manure, mud and wet bedding on teat skin end up in the milk unless prep removes them. Review pre-dip contact time, wiping routine, and whether cows are cleaner at some times of the year. Clip long udder hair, keep stalls clean and dry, and fix muddy lanes. High coliform counts often indicate teat hygiene problems.
Mastitis
Cows with infections shed bacteria into milk. Streptococcus agalactiae, for example, can push total counts up sharply, and so can some Staph aureus and environmental strep. If SCC is also high, mastitis is a likely contributor. Culture the bulk tank and suspect cows, and strip cows to catch clinical cases before they go in the tank.
Water and other sources
Wash water contaminated with bacteria can re-contaminate clean equipment. Test the well if you haven't recently, and check for backflow and treatment systems. Also check teat dip or sanitizer dilution, since a poor mix can undercut your whole prep routine.
A step-by-step approach
- Read the counts: which are high, and how high?
- Check wash and cooling first, since both are quick to verify.
- Swab equipment or run rinse samples to locate contamination.
- Review prep routine and teat condition.
- Culture the tank and high-SCC cows.
- Change one thing, re-test, and repeat.
Call your milking equipment dealer for a wash evaluation if you're stuck.
Resources
The National Mastitis Council and Extension provide troubleshooting charts, and UW farm extension has milk house and parlor checklists. Your buyer's field rep and state dairy regulator can explain required limits for your milk class and help locate certified labs. USDA AMS publishes dairy program information.
Most high counts are traced to something cheap and boring. The worn gasket always seems to be the last place anyone looks.