Repair, reset or redraw the line

MADISON, Wisconsin — Fix guidance line errors by working out whether the line itself is wrong, the position is wrong, or the machine settings are wrong. Often the cure is redrawing the line from a good start, recalibrating offsets, or shifting the line to match the existing field. Don't keep fighting a bad line; make a new one.

The line is just data. If it's wrong, you can change it.

Identify the kind of error

Describe what's happening in plain words:

Each points to a different cause. A uniform shift suggests an offset, a correction change or a day-to-day position difference. Wrong spacing suggests an implement width entry error. A jumping line suggests a signal or software problem.

Check the width and offsets

Make sure implement width, number of rows or sections, and spacing are entered correctly. A width entered a few inches off compounds across many passes and shows up as growing gaps or overlaps. Check implement offset left or right of centerline, and the antenna-to-hitch or antenna-to-implement distances, as your system asks.

Measure the implement physically instead of trusting the spec sheet if you've changed row units, extensions or wings. Then enter the measured value.

Shift or redraw the line

Most systems let you shift the line to match your existing position, so that the machine follows where the previous pass went or where the rows are. Use that for sideways shifts caused by day-to-day differences. For a bad A-B line, delete it and record a new one: drive straight and steady on a good fix, with correction active, and set points far enough apart to give an accurate heading.

For curved fields, use curve or adaptive modes, or record the line by driving the headland or the first pass carefully. For pivot fields, use the pivot pattern if available. Set the line on the first pass with care, since everything else follows.

Check the base layer

Line errors sometimes come from bad boundary or field data. Old boundaries, duplicated fields or lines saved under the wrong field name can load the wrong guidance. Clean up your field list, and make sure you've loaded the right field before starting. Check that coordinate and datum settings match between systems when you move files between brands.

If you use a base station or network for corrections, confirm its coordinates haven't changed. Moving a base without updating it shifts every line by the amount it moved.

Prevent repeats

Save lines under clear field names and note which year and which correction type recorded them. For repeat-pass tasks like planting and later spraying, use RTK or a repeatable correction so lines match, and mark the pass numbers in your records. Verify at the start of each job by checking against a known landmark or the previous pass.

Keep backups of your guidance lines, because rebuilding them in spring is an annoying chore. Our articles on software updates and backups explain how. For more help, contact your dealer, and see Iowa State's Ag Decision Maker, Purdue Extension and UW Extension farm resources. A good line is like a good fence: you only notice it when it's wrong, and then everyone has an opinion.

A habit that saves time: before leaving a field, save and name the line, and write down what it was created with, including the correction type, implement and width. Next time you load it, you'll know what to expect. If you share lines between machines or brands, test the transfer on a small field first, since some systems interpret lines or boundaries differently, and a shift of a few feet can appear. Check that the field, line and implement profile all match before you start working. And if a line is wrong and you're not sure why, stop after one pass, check the result against the ground, and fix it, instead of finishing the field and finding out later. One corrected pass is a minor delay. A whole field off line is a long conversation.