How do I repair a seed meter?

Clean, inspect, replace, test

COLUMBIA, Missouri — A seed meter is the part of the planter that counts. It picks up one seed at a time and hands it down the tube, and when it gets tired, you get skips, doubles and a stand that looks like a bad haircut. Repairing one is mostly careful disassembly, cleaning, replacing worn parts and testing on a bench or test stand before planting. It's a good winter job, with coffee.

Disconnect the planter from power, lock out any drives and wear gloves. If seed is treated, avoid breathing the dust and follow the label.

Remove and take it apart carefully

Remove the meter from the row unit and take a photo before you disassemble it. Empty seed and check for treatment buildup. Set the pieces on a clean towel in order. Look at the housing, the seed disc or belt, the singulator, the brush or finger assemblies, the drive shaft, the seals and the vacuum or air connections. Note the model and part numbers on each piece.

Don't pry on plastic parts. Many meters snap together, and brittle plastic cracks.

Clean away dust, talc and corrosion

Clean with soap and water or the cleaner recommended by the manufacturer, and let parts dry before reassembly. Seed treatments and lubricants leave a film. Remove it, since buildup changes how seed moves. Dry thoroughly. Look at the holes in the seed disc for wear, burrs and plugging; a worn hole releases seed badly. Check the surface for scratches.

Clean sensors gently, using a soft cloth. Scratched lenses cause bad readings.

Don't overlook the vacuum or air system that drives the meter. A cracked hose, loose clamp or worn fan belt reduces pickup pressure and mimics a bad disc. Check the vacuum gauge on the planter and compare it with the recommended range in your manual. If a single row is low while the others are fine, the leak is probably between the fan and that meter. Fix leaks before you start replacing meter parts, since a good meter on a bad hose still plants badly. Keep a few spare gaskets in the shop.

Replace the wear parts

Common wear items include seed discs, brushes, singulators, seals, gaskets and bearings. Compare the old and new parts. Worn brushes or fingers lose the light touch needed to remove doubles. A cracked housing or a warped disc leaks vacuum or air, and the meter can't pick up seed correctly. Replace anything that is warped, cracked or dull.

Many manufacturers sell a meter service kit that includes the parts that wear together. Buying the kit often costs less than replacing parts one at a time, and it avoids mismatched wear.

Reassemble and set it right

Follow the manual. Lubricate only where the manual says, since oil and grease attract dust and seed treatment. Don't over-tighten fasteners on plastic housings. Check the drive for smooth rotation by hand, and check that the seal faces make good contact.

Match the seed disc, brush or singulator to the crop and seed size you plan to plant. Corn, soybeans, sorghum and cotton use different configurations, and several seed sizes within a crop may need different adjustments.

Test before planting

A meter test stand, available through many dealers, measures skips, doubles and singulation at set speeds and vacuum levels. If you can't get on one, ask your dealer if they'll test your meters. Without a test stand, you can run the meter in the shop with seed and watch it drop seed onto a belt or tray.

Record results and adjust vacuum or other settings. Retest after changes. In the field, verify spacing by digging a few rows, and keep checking as seed lots change.

For safety, see the OSHA agriculture page and NIOSH agriculture resources. For planter setup and stand evaluation, see University of Nebraska CropWatch, Purdue Extension and Iowa State's Ag Decision Maker. Handling treated seed is covered by label directions and the EPA pesticides page.

Questions for your dealer: Is there a service kit for this meter? Can you test it on a stand? A seed meter in good shape does its work in total silence, which makes it a perfect employee.

When you finish, label the meter with the row number and the date, and keep matching sets together. A meter that has been bench-tested and set aside in a clean bag is ready to go the morning the soil is fit, and that is when you'll want every minute of daylight for planting.